Zenith Data Systems MT2000 User Manual

Page 112

Advertising
background image

5-24

Upgrades and Options

Replacing the Battery

Notice: Observe static precautions. Use an antistatic
wrist strap.

1. Power off the system and remove the side panel as

described earlier in this chapter.

2. Using your finger nail or a small pointed tool, gently

push down the top edge of the battery and pry the
battery out of its socket. Refer to Figure 5-9 for the
socket location.

3. Orient the new battery over its socket so the plus (+)

sign on the battery is facing up.

4. Carefully insert the bottom of the battery into the

socket connectors and gently push the battery into
the socket.

5. Press down on the battery until it is firmly seated in

its socket.

6. Replace the side panel and turn on the system.

7. Run the SCU to restore configuration settings to the

real-time-clock.

Advertising