Oven, Technical data, Dimensions – Zanussi ZCG 640 User Manual

Page 14: Provision for ventilation

Advertising
background image

14

Hob

Rear left burner (semi-rapid)

2000 W

Front left burner (rapid)

3000 W

Rear right burner (semi-rapid)

2000 W

Front right burner (auxiliary)

1000 W

Oven

Electric Grill

1650 W

Gas Oven burner

2700 W

Oven light

25 W

Total Electric Rating

1675 W

Supply voltage (50 Hz)

230 V

Technical Data

Appliance Class 2 sub class 1 and Class 1
APPLIANCE CATEGORY:

II2H3+

APPLIANCE GAS SUPPLY: Natural Gas G20 20mbar

Dimensions

Height

900 mm

Depth

600 mm

Width

600 mm

Oven Capacity

56 litres / 1.97 Cu. ft

BURNER

RAPID

SEMI-RAPID AUXILIARY OVEN

(large)

(medium)

(small)

POSITION

MAX MIN

MAX MIN

MAX

MIN

MAX

MIN

NOMINAL THERMAL
POWER (kW)

3.0

0.65

2.0

0.45

1.0

0.33

2.7

1.0

NOMINAL FLOW
RATE (m

3

/h)

0.286

0.062 0.190

0.043

0.095

0.031

0.257

0.095

NOZZLE REFERENCE

119

Adjust.

96

Adjust.

70

Adjust.

114

Adjust.

1/100 mm

NOMINAL THERMAL
POWER (kW)

2.8

0.65

2.0

0.45

1.0

0.33

2.7

1.0

NOMINAL FLOW
RATE (g/h)

202

47

144

32

72

24

195

72

NOZZLE REFERENCE

86

40

71

32

50

28

83

52

1/100 mm

NATURAL

GAS

20 mbar

TYPE OF

GAS

CHARACTERISTICS

LPG GAS

28-30/37

mbar

Instructions for the Installer

Important Safety Requirements

This appliance must be installed in accordance with
the Gas Safety (Installation and Use) Regulations
(current addition) and the I.E.E. Wiring Regulations.
Detailed recommendations are contained in the
following British Standard Codes of Practice - B.S. 6172,
B.S. 5440: Part 2 and B.S. 6891: Current Editions.
For appliances installed in the Republic of Ireland please
refer to NSAI- Domestic Gas Installation I.S. 813
Current Editions and the ETCI Rules for Electrical
Installations.

Provision for Ventilation

The room containing the cooker should have an air
supply in accordance with B.S. 5440: Part 2: Current
Editions.
The following requirements for ventilation must be
met.

The cooker should not be installed in a bed sitting room
with a volume of less than 20m

3

, if it is installed in a room

of volume less 5m

3

an air vent of effective area of 110cm

2

is required; if it is installed in a room of volume between
5m

3

and 10m

3

, an air vent of effective area 50cm

2

is

required, while if the volume exceeds 11m

3

no air vent is

required. However, if the room has a door which opens
directly to the outside, no air vent is required even when
the volume is between 5m

3

and 11m

3

.

If there are other fuel burning appliances in the same
room, B.S. 5440: Part. 2: Current Editions should be
consulted to determine the requisite air vent
requirements.

For appliances installed in the Republic of Ireland
please refer to the NSAI- Domestic Gas Installation I.S.
813 Current Editions Table Four.

VALUE =

Hs 49.92 MJ/Kg

Ws 82.09 MJ/ m

3

VALUE =

Hs 37.78 MJ/m

3

Ws 50.72 MJ/ m

3