2

Xantrex PROwatt™ SW Sine Wave Inverter Owner’s Guide

Introduction

Ease of Use

Superior features and rugged durability have been combined with
ease of use:

The unit is compact, light weight, and easy to install.

You can power loads directly from the dual GFCI-protected
AC receptacles on the front panel.

Easy-to-read digital display on the front panel lets you monitor
system performance at a glance.

The optional PROwatt Remote Panel lets you control the
inverter from a convenient location—up to 25 feet (7.6 m)
away—while the inverter itself is mounted out of sight and
close to the batteries.

A convenient USB port powers most modern electronic
products.

Comprehensive Protection

The PROwatt SW Inverter is equipped with the following protection
features:

GFCI protection

De-energizes the AC circuits and thereby
protects the user from electric shock if a ground
fault occurs.

Low battery voltage
alarm

Alerts you if the battery has become discharged
to 11 V or lower.

Low battery voltage
shutdown

Automatically shuts the inverter down if the
battery voltage drops below 10.5 V. This feature
protects the battery from being completely
discharged. Within five minutes after
shutdown, the unit recovers automatically once
the battery voltage reaches above 11.5 Vdc.
After five minutes, the unit turns itself off.

High battery voltage
shutdown

Shuts the inverter down automatically if the
input voltage rises to more than 15.5 V. Within
five minutes after shutdown, the unit recovers
automatically once the battery voltage falls
below 15.5 Vdc. After five minutes, the unit
turns itself off.

AC output overload
shutdown

Shuts the unit down automatically if a short
circuit occurs or if the loads attached to the
inverter exceed the operating limits.

Over temperature
shutdown

Turns the inverter off if its temperature rises
above an acceptable level. Within five minutes
after shutdown, the unit recovers automatically
once the temperature of the unit cools down.
After five minutes of operating in high
temperature, the unit turns itself off.

PROWatt SW Inverter NA.book Page 2 Wednesday, August 5, 2009 2:24 PM