Figure 5 configuration for heavy loads – Xantrex Technology PROWATT SW SW 2000 User Manual

Page 22

Advertising
background image

12

Xantrex PROwatt™ SW Sine Wave Inverter Owner’s Guide

Installation

Cabling Procedure

Consult the following configurations and determine a match
specific to your installation and follow the installation procedure
“To connect the battery cables:” that comes next.

To connect the battery cables:

1.

Make sure the inverter is off and assemble the terminated
cables (cables with connectors) that you bought.

2.

Line up the connectors that will join the cables to the battery,
battery selector switch, and fuse (or circuit breaker).

Figure 4 Configuration for Normal Loads

TO OTHER
DC LOADS

FUSE OR
CIRCUIT
BREAKER

FUSE OR
CIRCUIT
BREAKER

GROUND TO
VEHICLE
CHASSIS

GROUND TO
VEHICLE
CHASSIS

VEHICLE
STARTING
BATTERY

FROM ALTERNATOR
OR CHARGER

GROUND TO
VEHICLE
CHASSIS

DEEP-CYCLE
AUXILIARY
BATTERY

ISOLATOR

TO VEHICLE

Figure 5 Configuration for Heavy Loads

ALL

OFF

2

1

ALL

OFF

2

1

TO OTHER
DC LOADS

GROUND TO
VEHICLE
CHASSIS

GROUND TO
VEHICLE
CHASSIS

BATTERY
SELECTOR
SWITCH

BATTERY
SELECTOR
SWITCH

VEHICLE
STARTING
BATTERY

FROM ALTERNATOR
OR CHARGER

DEEP-CYCLE
BATTERY

DEEP-CYCLE
BATTERY

DEEP-CYCLE
BATTERY

DEEP-CYCLE
BATTERY

ISOLATOR

TO VEHICLE

GROUND TO
VEHICLE
CHASSIS

FUSE OR
CIRCUIT
BREAKER

FUSE OR
CIRCUIT
BREAKER

FUSE OR
CIRCUIT
BREAKER

FUSE OR
CIRCUIT
BREAKER

PROWatt SW Inverter NA.book Page 12 Wednesday, August 5, 2009 2:24 PM

Advertising
This manual is related to the following products: