wait until the ‘Expect’ string is matched before it proceeds to set 2, and so on for the rest of the
script. When both the ‘Expect’ and the ‘Send’ fields of the current set are empty, the Prestige will
terminate the script processing and start PPP negotiation. This implies two things: first, the sets
must be contiguous; the sets after an empty one are ignored. Second, the last set should match the
final message sent by the server. For instance, if the server prints

login successful.
Starting PPP...

after you enter the password, then you should create a third set to match the final “

PPP...

” but

without a “Send” string. Otherwise, the Prestige will start PPP prematurely right after sending
your password to the server.

If there are errors in the script and it gets stuck at a set for longer than the “Dial Timeout” in menu
2 (default 60 seconds), the Prestige will timeout and drop the line. To debug a script, go to Menu
24.4 to initiate a manual call and watch the trace display to see if the sequence of messages and
prompts from the server differs from what you expect.

Figure 4-4.

Menu 11.4 – Remote Node Setup Script

Menu 11.4 – Remote Node Setup Script

Active= No

Set 1:

Expect=
Send=

Set 2:

Expect=

Send=

Set 3:

Expect=

Send=

Set 4:

Expect=
Send=

Set 5:

Expect=
Send=

Set 6:

Expect=

Send=

Press ENTER to CONFIRM or ESC to CANCEL: