Zebra Technologies RW SERIES User Manual

Page 17

Advertising
background image

17

RW Series User Guide

directly under the battery being charged will turn on if the
battery is properly inserted.

The indicators under the battery will allow you to monitor

the charging process per the following table:

Battery Status Indicators

Amber LED

Green LED

Battery Status

On

Off

Charging

On

Flashing

80% charged (O.K. to use)

Off

On

Completely Charged

Flashing

Off

Fault

Important • A fault condition is caused by a problem with the battery.

The charger may indicate a fault because the battery is too hot or cold

to charge reliably. Try to charge the battery again when it returns to the

room’s ambient temperature. If the Amber indicator starts flashing on

the second attempt, the battery should be discarded. Always dispose of

batteries in a proper manner. Refer to Appendix D

LI 72-4 Charger Cycle Times :

RW 420

RW 220

Battery 80% Charged

2.5 Hrs

1.25 Hrs.

Battery Fully Charged

5 Hrs.

2.5 Hrs.

Note • Charge times are for completely discharged batteries.

Partially discharged Battery Packs will take less time than

listed in the chart to reach a fully charged state. Once Battery
Packs have reached 80% of their charge capacity they may be
used, but it is recommended that you allow the batteries to
reach a full charge to maintain maximum battery life.

The UCLI72-4 Quad Charger’s safety features will stop

charging a battery after six hours regardless of its charge
state.