Reconditioning (Equalizing) Flooded Type
Batteries

To recondition your batteries (on the vehicle):

1. Disconnect all loads from the battery by removing

battery cables or by opening a disconnect switch.

2. Apply AC power to the Duracell® Charger, and turn the

AC power

ON

/

OFF

switch to

ON

.

3. Connect the red positive (+) clip of the cables to the

positive (+) terminal of the engine battery.
The battery’s positive terminal is usually larger in
diameter than the negative terminal. In most vehicles, the
battery’s positive terminal has a red wire connected to it.

WARNING: Explosion hazard

Battery reconditioning feature works only on flooded lead-acid
batteries. Do not attempt to recondition sealed lead-acid batteries.

WARNING: Explosion hazard

During the battery reconditioning process, the battery generates
potentially flammable gases. Follow all the battery safety
precautions listed in this guide. Ventilate the area around the battery
thoroughly and ensure that there are no sources of flame or sparks
in the vicinity.

CAUTION

Turn off or disconnect all loads on the battery during
reconditioning. The voltage applied to the battery during
reconditioning may be above the safe levels for some loads. Be sure
to check battery electrolyte before and after reconditioning. Fill
only with distilled water.

Important:

The battery reconditioning mode has a 4 hour

timing limit.

Duracell_Charger15.book Page 6 Friday, June 15, 2007 2:34 PM