Float charge – Xantrex Technology Link 2000 User Manual

Page 37

Advertising
background image

B-2

Float Charge

The float charge is a maintenance mode in which the output
voltage of the charger is reduced to a lower level, typically
about 13.5 volts to maintain the battery’s charge without
losing electrolyte through gassing. In the float mode, the
charger will initiate a new charge cycle under any of these
conditions:

AC power is disconnected and reconnected

current demand on charger exceeds the battery recharge
current setting

The chart in Figure B-1 shows the three-stage charging
profile.

Figure B-1 Three-stage charging profile

DC Current

Time

DC Voltage

Charging started

Bulk stage

Absorption
stage

Float stage

Constant current
at maximum
charge rate

Constant voltage
at Absorption
voltage setting

Load current on demand

Constant voltage
at the Float
voltage setting

Duracell_Charger15.book Page 2 Friday, June 15, 2007 2:34 PM