Heating performance - with air handler, Heating performance - with furnace coils – York 090 User Manual

Page 6

Advertising
background image

279104-YTG-B-0307

6

Unitary Products Group

COP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric

power input during the same period.

— = Not Applicable.

COP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric

power input during the same period.

— = Not Applicable.

HEATING PERFORMANCE - With Air Handler

UNIT

MODEL*

COIL

1

MODEL

ARI HEATING

2

OUTDOOR TEMP

3

47

°F

17

°F

HSPF

-3

°F

7

°F

17

°F

27

°F

37

°F

47

°F

57

°F

MBH COP MBH COP

STD MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW

E1RA036S(25,4

F2RP/F2FP036 34.0 3.00 20.4

2.16

7.2

15.5 2.40 15.6 2.54 20.4 2.80 24.9 3.03 29.9 3.20 34.0 3.32 38.5 3.50

AHP36,42

34.0 3.00 20.4

2.16

7.2

15.5 2.40 15.6 2.54 20.4 2.80 24.9 3.03 29.9 3.20 34.0 3.32 38.5 3.50

E2RA048S(25,46

F2FP048

37.0 3.08 31.4

2.32

7.5

20.8 3.64 26.1 3.80 31.4 3.97 36.7 4.13 40.1 4.27 47.0 4.47 54.6 4.71

AHP48,60

37.0 3.08 31.4

2.32

7.5

20.8 3.64 26.1 3.80 31.4 3.97 36.7 4.13 40.1 4.27 47.0 4.47 54.6 4.71

E1RA060S(25,46)

F2FP060

58.5 3.12 39.0

2.34

7.6

26.0 4.48 32.5 4.68 39.0 4.88 42.1 4.98 45.1 5.07 58.5 5.49 65.0 5.70

AHP48,60

58.5 3.12 39.0

2.34

7.6

26.0 4.48 32.5 4.68 39.0 4.88 42.1 4.98 45.1 5.07 58.5 5.49 65.0 5.70

1. Rated CFM same as for cooling.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no supplemental

electric heat operation.

3. Integrated heating capacities include the effect of defrost cycles in the temperature range where they occur.

HEATING PERFORMANCE - With Furnace Coils

UNIT

MODEL*

COIL

1

MODEL

ARI HEATING

2

OUTDOOR TEMP

3

47

°F

17

°F

HSP

F

-3

°F

7

°F

17

°F

27

°F

37

°F

47

°F

57

°F

MBH COP MBH COP STD MBH

KW

MBH

KW

MBH

KW

MBH

KW

MBH

KW

MBH

KW

MBH

KW

E1RA036S25,46

G2FD042(S,H)21

34.0

3.00

20.2

2.14

7.2

11.3

2.40

15.7

2.58

20.2

2.77

24.7

2.94

29.5

3.15

34.0

3.32

40.5

3.50

G1NA036S17L

35.0

3.20

22.0

2.26

7.6

13.3

2.62

17.7

2.74

22.0

2.85

23.3

2.71

24.5

2.57

35.0

3.21

39.3

3.32

G1NA048S21D

35.0

3.20

22.0

2.26

7.6

13.3

2.62

17.7

2.74

22.0

2.85

23.3

2.71

24.5

2.57

35.0

3.21

39.3

3.32

G1UA048S21

34.0

3.00

20.2

2.14

7.2

11.3

2.40

15.7

2.58

20.2

2.77

24.7

2.95

29.5

3.15

34.0

3.32

40.5

3.50

G1FA048S21

34.0

3.00

20.2

2.14

7.2

11.3

2.40

15.7

2.58

20.2

2.77

24.7

2.95

29.5

3.15

34.0

3.32

40.5

3.50

FC/MC/PC35*3X

34.0

3.00

20.2

2.14

7.2

11.3

2.40

15.7

2.58

20.2

2.77

24.7

2.95

29.5

3.15

34.0

3.32

40.5

3.50

FC/MC/PC/UC36*3X

34.0

3.00

20.2

2.14

7.2

11.3

2.40

15.7

2.58

20.2

2.77

24.7

2.95

29.5

3.15

34.0

3.32

40.5

3.50

FC/MC/PC/UC42*3X

34.0

3.00

20.2

2.14

7.2

11.3

2.40

15.7

2.58

20.2

2.77

24.7

2.95

29.5

3.15

34.0

3.32

40.5

3.50

E2RA048S25,46

G2FD048(S,H)21,24

47.0

3.02

31.2

2.32

7.5

21.0

3.56

26.1

3.75

31.2

3.94

36.3

4.13

40.1

4.32

47.0

4.56

54.1

4.59

G1NA048S21D

47.0

2.96

31.2

2.30

7.5

20.7

3.52

25.9

3.75

31.2

3.98

35.2

4.13

39.2

4.29

47.0

4.65

52.3

4.88

G1UA048S21

47.0

3.00

31.2

2.30

7.50

20.9

3.60

26.1

3.79

31.2

3.98

36.3

4.16

42.0

4.39

47.0

4.56

54.0

4.61

G1FA048S21

47.0

3.00

31.2

2.30

7.5

20.9

3.60

26.1

3.79

31.2

3.98

36.3

4.16

42.0

4.39

47.0

4.59

54.0

4.61

FC/MC/PC/UC48C3X

47.0

3.02

31.2

2.32

7.5

21.0

3.56

26.1

3.75

31.2

3.94

36.3

4.13

40.1

4.32

47.0

4.56

54.1

4.59

FC/MC/PC/UC48D3X

47.0

3.02

31.2

2.32

7.5

21.0

3.56

26.1

3.75

31.2

3.94

36.3

4.13

40.1

4.32

47.0

4.56

54.1

4.59

E1RA060S25,46

G2FD060(S,H)24

58.0

3.20

38.5

2.40

7.7

25.5

4.29

32.0

4.50

3.9

4.70

42.1

4.91

45.7

5.11

58.0

5.31

64.5

5.51

G1UA060S24

58.0

3.20

38.5

2.40

7.7

25.5

4.29

32.0

4.50

3.9

4.70

42.1

4.91

45.7

5.11

58.0

5.31

64.5

5.51

G1FA060S24

58.0

3.20

38.5

2.40

7.7

25.5

4.29

32.0

4.50

3.9

4.70

42.1

4.91

45.7

5.11

58.0

5.31

64.5

5.51

FC/MC/PC/UC60C3X

58.0

3.20

38.5

2.40

7.7

25.5

4.29

32.0

4.50

3.9

4.70

42.1

4.91

45.7

5.11

58.0

5.31

64.5

5.51

FC/MC/PC/UC60D3X

58.0

3.20

38.5

2.40

7.7

25.5

4.29

32.0

4.50

3.9

4.70

42.1

4.91

45.7

5.11

58.0

5.31

64.5

5.51

1. Rated CFM same as for cooling.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no supplemental elec-

tric heat operation.

3. Integrated heating capacities include the effect of defrost cycles in the temperature range where they occur.