Setting the time zone, Displaying the time zone, Clearing the time zone – 3Com WX4400 3CRWX440095A User Manual

Page 125: Configuring the summertime period

Advertising
background image

Configuring and Managing Time Parameters

125

Setting the Time

Zone

The time zone parameter adjusts the system date, and optionally the
time, by applying an offset to UTC.

To set the time zone, use the following command:

set timezone zone-name {-hours [minutes]}

The zone name can be up to 32 alphanumeric characters long, with no
spaces. The hours parameter specifies the number of hours to add to or
subtract from UTC. Use a minus sign (-) in front of the hour value to
subtract the hours from UTC.

To set the time zone to PST (Pacific Standard Time), type the following
command:

WX1200# set timezone PST -8
Timezone is set to 'PST', offset from UTC is -8:0 hours.

Displaying the Time Zone

To display the time zone, use the following command:

display timezone

For example, to display the time zone, type the following command:

WX1200# display timezone
Timezone set to 'PST', offset from UTC is -8 hours

Clearing the Time Zone

To clear the time zone, use the following command:

clear timezone

Configuring the

Summertime Period

The summertime period offsets the system time +1 hour and returns it to
standard time for daylight savings time or a similar summertime period
that you set.

Configure summertime before you set the time and date. Otherwise,
summertime’s adjustment of the time will make the time incorrect, if the
date is within the summertime period.

To configure the summertime period, use the following command:

set summertime summer-name
[start week weekday month hour min
end week weekday month hour min]

Advertising