Chapter 4 Parameter Settings|DD Series


4-27

accurate (1:1000).

Door Control Mode

Control mode VF

VFPG

SVC

FOCPG

FOCPM

Factory setting: 3

Settings 0: Distance control mode

1: Reserved

2: Multi-step speed control mode

3: Speed control mode

0: Distance control mode

Set encoder PG pulses accurately to ensure precise door width estimation. Door width is measured and

stored by Auto-tuning. It operates the door for speed switch and completed position by counting the PG

pulses. In this mode, position function will be executed whenever power again and operates with low

speed to the 0% or 100% door width by the operation direction.

Door Close
Holding Speed

Open Door (R EV)

Door Open Limi t

0.0%

100.0%

Close Door (FWD)

04.00

Door Open

Speed

by Ini tial

04.08

Door Open
Acceleration

Time 1

04.09

Door Open
Deceleration

Time 1

04.03

Door Open H igh Speed 1

04.05

Door Open
Final Speed

04.01

Door Open D istance
by Ini tial Speed

04.04

Door Open

Final Speed

Start

by

04.06

Door Open
by Holding

Speed Start

04.07

Door Open
Holding Speed

05.03

Door Close

High Speed 1

D oor Close

Accel er ation Time 1

05.05

05.04

05.06

Door Close

Hol ding

Speed Start

with

05.07

05.09

05.01

Door Close

Distance by
Ini tial Speed

05.00

Door Close

Ini tial Speed

Door Close Limit

Door Close
Final Speed

Door Close
Final Speed

Door Close
Final Speed

Start

05.08

2: Multi-step control mode

The drive is controlled by Sensorless control. For operating the door, it uses three multi-input (level

trigger) and operation direction (FWD/REV) to deal with speed switch and limit switch to deal with

completed position. (4th logic signal: open: 0; close: 1).