3Com recommends that the cable (B) between the Fast
Ethernet hubs is no longer than 5m (16.4ft). This allows the
maximum hub-to-workstation cable length (A or C) of 100m
(328ft) to be used, as shown in Figure 3.

Figure 3 Configuration Rules and Example of a Fast Ethernet
(100Mbps) Network

Ethernet (10Mbps) Configuration Rules

You can connect a maximum of four Ethernet (10Mbps)
hubs in series between workstations, or between a
workstation and a non-repeater piece of equipment (such as
a switch). Each cable must not exceed 100m (328ft). An
example is shown in Figure 4.

Figure 4 Example of an Ethernet (10Mbps) Network

5m (16.4ft)

100m (328ft)

100m (328ft)

Dual

Speed

Hub 16

100Mbps

Hub

Example:

B

C

A

Hub

Hub

Workstation

Workstation

Workstation

Workstation

Switch

100Mbps
link

Dual

Speed

Hub 16

10Mbps

Hub

10Mbps

Hub

10Mbps

Hub

Workstation

Workstation

Switch

10Mbps
link

Example: