Initializing the system performance series, Important – 3M 2475 User Manual

Page 14

Advertising
background image

Initializing the System

Performance Series

10

!

Important

1. Initialization will erase all memorized parameters and restore factory default values.

2. If Pump Mode (factory default) is desired, initialization is not required.

3. If software is upgraded, the system must be re-initialized.

Initialization instructions
for Pump Mode (factory
default)

Pump mode assigns each Call Station to a single number (1 through 24).
Pump mode is used when there are 2 speakers per M.P.D., and each speaker
serves one side of the dispenser.

Procedure 1: Press and hold the ALL CALL key while applying power to the

Selector.

OR

Procedure 2: Reset or remove power from the Station Selector using one of

the following methods:

a. Unplug the RS485 cable.

b. Press and hold the STD BY key while entering the numeric code 911.

Initialization
Instructions for Island
Mode

Island mode assigns each Call Station to two consecutive numbers (1&2,,
3&4, …….). Island mode is used where a single speaker serves both sides of a
dispenser.

Procedure 1: Press and hold the HOLD key while applying power to any

Selector.

OR

Procedure 2: Reset or remove power from any Station in one of the

following ways.

a. Unplug the RS485 cable.

b. Press and hold the STD BY key while entering the numeric code 911.

Resetting the Station

To reset only the station selector:

Selector

1. Press and hold the STD BY key.

(Reset)

2. Enter the numeric code: 911.

Resetting the System

To reset only the entire system:

(Reset)

1. Press and hold the STD BY key.

2. Enter the numeric code: 8642.

DEFINITIONS:

1) Power On Reset:

Turning off power, and then turning it back on. Commonly referred to as a “Cold Boot”.

2) Reset:

Restarting the micro controller firmware. Commonly referred to as the “Warm Boot.”

2) Re-Initialize:

Over writes the EEPROM memory with factory default values. This process also selects “Pump” or “Island”

mode of operation

3) Programming Mode:

change the EEPROM memory from factory default values to user preferences

Init PUMP Mode
‘TALK’ = Yes
1:PUMP MODE

Init ISLAND Mode
‘TALK’ = Yes