Appendix C — Troubleshooting

C-4

Ethernet Power Supply User s Guide

Problem

Resolution

The end device
operates, but
there is no data
link.

Verify that:
• The Port LED on the Ethernet Power

Supply front panel is lit continuously.

• The "Data" and "Data & Power" ports

correspond.

• If an external splitter is in use, replace

it with a new splitter. Discard the
faulty splitter.

• You are using a standard UTP

Category 5 cable, including all 8 wires
(4 pairs), and is 100m or less in
length between the switch and the
end device.

• You are not using any crossover

twisted pair wires.

• The Ethernet Power Supply is

connected to a switch or hub with a
good RJ-45 patch cord connection.

In addition, try to:
• Bypass the long twisted pair cable

and bring the end device close to the
Ethernet Power Supply and connect
to one of the ports using a short
cable. If this works, there is probably
a faulty connection or short on the
long cable, or one bad RJ-45
connection along the line.

Advertising