10. TROUBLESHOOTING

N.B.:

in case of a fault, the display backlighting flashes together with the error code.

To keep the boiler efficient and safe, have it checked by the authorised Service Centre at the end of every operating period.
Careful servicing ensures economical operation of the system.
Do not clean the outer casing of the appliance with abrasive, aggressive and/or easily flammable cleaners (e.g.: petrol,
alcohol, and so on). Always switch off the appliance before cleaning it (see section 7 Switching off the boiler).

11. ROUTINE MAINTENANCE INSTRUCTIONS

Faults are shown on the display with an error code (e.g.: E 01):

CODE

DISPLAYED

FAULT

CORRECTIVE ACTION

E01

Failed ignition shutdown

Press and hold down “

R” for at least 2 seconds. If this fault persists, call the

Authorised Service Centre.

E02

Safety thermostat tripped

Press and hold down “

R” for at least 2 seconds. If this fault persists, call the

Authorised Service Centre.

E03

Flue thermostat/ flue pressure
switch tripped

Call the Authorised Service Centre.

E04

Shutdown after 6 consecutive
flame losses

Press and hold down “

R” for at least 2 seconds. If this fault persists, call the

Authorised Service Centre.

E05

Flow sensor failure

Call the Authorised Service Centre.

E06

DHW sensor fault

Call the Authorised Service Centre.

E10

Hydraulic pressure switch
block

Check that the pressure in the system is correct; See section 6. If this fault
persists, call the Authorised Service Centre.

E25/E26

Probable blocked pump safety
trip

Call the Authorised Service Centre.

E35

Parasite flame (flame error)

Press and hold down “

R” for at least 2 seconds. If this fault persists, call the

Authorised Service Centre.

E96

Switching off due to reductions
in power supply

RESET is automatic. If this fault persists, call the Authorised Service Centre

To RESET the boiler, press and hold down “R” for at
least 2 seconds. If this fault persists, call the Authorised
Service Centre.

N.B.:

5 reset attempts can be performed after which

the boiler shuts down. To reset again, switch off the
boiler for a few seconds.

Figure 3

0607_1205

RESETTABLE

faults