Expansion vessel, Warning – DE DIETRICH MS 24 BIC User Manual

Page 67

Advertising
background image

67

71.06199.02 - EN

INSTALLATION INSTRUCTIONS

EXPANSION VESSEL

The boiler features a standard 7.5-litre expansion vessel with a pre-charge pressure of 1 bar. The maximum volume of water in
the system is calculated according to hydrostatic pressure at an average water temperature of 80°C (flow: 95°C return: 75°C).

Hydrostatic pressure (m)

5

6

7

8

9

10

Maximum system volume (l)

138

131

119

107

97

87

G”3/4 HEATING FLOW

G”1/2 DOMESTIC HOT WATER OUTLET

G”3/4 HEATING RETURN

G”1/2 DOMESTIC COLD WATER INLET

G”3/4 GAS INLET TO BOILER

WARNING

Tighten the boiler nipple water connections with care (maximum tightening torque 30 Nm).