Micro ir-100 controls, Operation – RIDGID micro IR-100 User Manual

Page 13

Advertising
background image

micro IR-100 Non-Contact Infrared Thermometer

Ridge Tool Company

11

micro IR-100 Controls

Figure 8 – micro IR-100 Display/Buttons

Continuous Measurement (Scanning) Mode

The micro IR-100 can be locked ON to allow measurements with-

out holding the trigger. Make sure that the unit is pointed in a safe

direction away from any bystanders before turning ON. Turn the

micro IR-100 ON by squeezing and holding the trigger. While hold-

ing the trigger, press and release the menu button. The SCAN and

Lock icons will be ON. Release the trigger, and the micro IR-100 will

continuously update the measured temperature until the trigger

switch is squeezed and released again.

Laser Enabled/Disabled

If needed, the lasers used for aiming can be turned off to help con-

serve battery life. If this is done, extra care must be used when aim-

cant changes in ambient temperature (more than 30°F or 17°C)

are encountered, allow fifteen minutes for the micro IR-100 to

adjust for best accuracy.
Obstructions – Steam, dust, smoke and other obstructions

like glass or plastic between the micro IR-100 and the surface

being measured can decrease accuracy. These obstruct the

unit optics or give false readings (measure the temperature of

the glass instead of the surface). Do not use when obstructions

are present.
Consider these factors prior to operating the micro IR-100.

3. Make sure that all equipment has been properly inspected.

Operation

Turning ON and OFF (Taking Measurements)

1. Hold the micro IR-100 by the handle grip and point it at the

surface to be measured. Keep away from any electrical, mov-

ing or hot parts. Make sure that the unit is pointed in a safe di-

rection away from any bystanders before turning ON.

2. Squeeze the trigger to turn the micro IR-100 ON. When the

trigger is squeezed, the SCAN icon will be ON, and the micro

IR-100 will continuously update the displayed current temper-

ature value and display the maximum temperature value since

the unit was turned ON.
The micro IR-100 can be moved slowly over the surface to lo-

cate hot or cool areas. See the High Alarm and Low Alarm sec-

tions for information on high and low alarm settings.

3. When the trigger is released, the HOLD icon will be ON. The

micro IR-100 will automatically turn OFF after seven seconds

unless the unit is in Continuous Measurement mode.

Menu Button

Trigger

LCD Display

Down Button/-

Backlight

Laser