HDB-E Si |

21

InStallatIOn

Safety

InStallatIOn

7. safety

Only a qualified contractor should carry out installation. commis-

sioning. maintenance and repair of the appliance.

7.1 general safety instructions

We guarantee trouble-free operation and operational reliability

only if the original accessories and spare parts intended for the

appliance are used.

!

Material damage

Observe the maximum inlet temperature. The appliance

can be damaged by higher temperatures.

7.2 regulations. standards and instructions

Note

Observe all applicable national and local instructions and

regulations. e.g. DIN 1988 / DIN EN 806 in Germany.

- The protection rating IP 25 (hoseproof) can only be ensured

with a correctly fitted cable grommet.

- The specific electrical resistance of the water must not fall

below that stated on the type plate. In a linked water net-

work. observe the lowest electrical water resistance (see

chapter “Specification / Application areas”). Your water

supply utility will advise you of the specific electrical water

resistance or conductivity.

8. appliance description

8.1 standard delivery

- Mounting bracket

- Twin nipple

- Cross-piece

- DHW tee

- Flat gaskets

- Sieve

- Flow limiter

- Plastic profile washer

- Plastic cap

- Flexible plastic couplings

- Cap and back panel guides

8.2 accessories

taps

- MEKD - Pressure-tested kitchen tap

- MEBD - Pressure-tested bath tap

Plug g ½ a
These plugs are required if you use pressure-tested taps for fin-

ished walls other than the ones recommended by us.

installation sets for installation on finished walls

- Solder fitting - copper pipe for solder connection Ø 12 mm.

- Compression fitting - copper pipe.

- Compression fitting - plastic pipe (suitable for Viega: Sanfix-

Plus or Sanfix-Fosta).

universal mounting frame
Mounting frame with electrical connections.

Pipe assembly dHB water plug-in couplings
2 water plug-in couplings allow the appliance to be connected to

the available water plug-in connections of a DHB.

load shedding relay (lr 1-a)
The load shedding relay which needs to be installed in the dis-

tribution board provides priority control for the instantaneous

water heater when operating. for example. electric storage heat-

ers simultaneously.

9. Preparations

f

f Flush the water line thoroughly.

taps/valves

f

f Use appropriate pressure-tested Taps (see “Appliance

description / Accessories” chapter). Open taps are not

permitted.

A safety valve is not required.

!

Material damage

If plastic pipework systems are used. take into account

the maximum inlet temperature and the maximum pres-

sure (see chapter “Specification / Data table”).

Permissible water pipe materials

- Cold water inlet pipe:

Galvanised steel pipe. stainless steel pipe. copper pipe or

plastic pipe

- DHW outlet pipe:

Stainless steel pipe. copper pipe or plastic pipe

!

Material damage

If plastic pipework systems are used. take into account

the maximum inlet temperature and the maximum pres-

sure (see chapter “Specification / Data table”).

Flow rate

f

f Ensure that the flow rate (see chapter “Specification / Data

table”. On) for switching on the appliance is achieved.

f

f Increase the mains water pressure if the required flow rate is

not achieved with the draw-off valve fully opened.