1. Operating instructions

for the user and the qualified installer

The RTF-Z digital controller enables individu-

al control of the heating mats. There are four
operating programmes.

When connected to the mains electrical supply
the controller switches on and regulates the
floor heating to a preset temperature. The

„heating operating symbol “ is displayed.

After setting the time the controller automa-
tically switches to the timer programme.

By means of the self learning function of the

RTF-Z, the start-time will be set directly into
the timer-program, from which the comfort
temperature will be achieved. Due to this, the
start of the heating-time will be before the
adjusted starting time.

The self-learning-function is activated by the
factory, if wished it can be deactivated within
the adjustment mode.

Switching ON & OFF

To switch off, press the M button and hold
for 3 seconds, the display will then show OFF.
To switch on again press and hold the M
button for 3 seconds. The controller will
switch on again to its most recent setting.

In the off position frost protection is
not provided.

1 Mode - select an operating mode or

function by repeated pressing

2 Reset - restore the factory setting.

Briefly depress the flush-fitting push-

button with a non-conductive blunt object.

3 Increase the set value
4 Decrease the set value
5 Confirm the set value
6 Display

1

2

3

4

5

6

8966.02

8967.01

Functions

Heating operating
Time

P

Program selection

Timer programs
P1 = Program 1
P2 = Program 2
P3 = Program 3

Operating modes
7

Frost protection
Off-peak temperature
Comfort temperaure
Timer program

Days of the week
1-5 = Monday - Friday
6+7 = Saturday + Sunday

Start / end time in the timer program
S1 = 1st start time

E1 = 1st end time

S2 = 2nd start time

E2 = 2nd end time

S3 = 3rd star t time

E3 = 3rd end time

Value indicator
Setpoint floor temperature
(Guide figure, e.g. 2.5 = approx.
25 °C) or time

Time segments of timer

Comfort temperature
Off-peak temperature

Factory settings

Timer program switching times

Floor temperatures of operating modes

Frost protection

1.0

=

^ approx. 10

Guide figure

°C

Off-peak temperature

1.8

=

^ approx. 18

Comfort temperature

2.5

=

^ approx. 25

Temperature setting limits
Max. Floor temperature

4.0

=^ approx. 40

Min. Floor temperature

1.0

=^ approx. 10

Displays

or

1.1 First start-up

After connecting to the mains supply, the following displays appear:

for approx. 5 seconds . . .

. . . then alternately

probe defective or not connected

1.2 Setting the time and day of the week

Press push-buttom M until the function symbol is displayed.

Hour

Push-
button

+

or

Minutes

Push-
button

Day of the week

+

or

Push-
button

OK

OK

OK

+

or

6

12

18

24

0

2.5

6

12

18

24

0

6

12

18

24

0

6

12

18

24

0

00:00

1 2 3 4 5

6

6

12

18

24

0

7

8

8

8

8

8

8

8

8

P

88:88

00

:00

00

:00

1

Advertising