1.5 Adjsutment

(can only be set in frost protection mode)

Individual settings of operating parameters, which remain stored even in the event of a power failure.

Select the frost protection 7 operating
mode;

1

6

12

18

24

0

Simultaneously press M and OK for 3
seconds, until „Just“ is displayed;

Display setting

1.3 Operating modes

1.4 Changing the timer program

To call up the desired operating mode, press push-button M until the respective symbol appears in the display.

The switching times of the timer program can be adapted to the prevailing wishes of the user.

Allocating the daily program

A program must be allocated to each day of
the week, there is no day which doesn’t have
a program allocation. To remove a day from a

program, the day in question must be
allocated to another program.

Press push-button M until the

P

, Pr 1

(Program 1) symbol and the days
allocated to the program are displayed;

1

6

12

18

24

0

P

2 3 4 5

Switch between the programs (Pr 2, Pr 3,
Pr 1, . . .) using the

+

push-button;

6

6

12

18

24

0

7

P

Press the

push-button, to display the days

not allocated to the selected program, in
flashing mode;

1

6

12

18

24

0

P

2 3 4 5

6

Press the OK push-button to add the
selected day to the selected program, or
switch to the next as yet unallocated day

using the

push-button;

Repeat steps as described, until all days

have been allocated as desired;

Press push-button M to terminate the
process – the display changes to the frost

protection symbol.

Program switching times

Press push-button M until the symbol

is displayed;

1

6

12

18

24

0

P

1

P

1

S

1

S

1

2.5

Press the OK push-button to switch to

the programming mode, and select the
switching program to the changed using

the

+

or

push-button;

6

12

18

24

0

Press the OK push-button to switch to
the 1st start time (S1) of the selected
program;

6

12

18

24

0

P

1

P

1

S

1

S

1

06.00

Press the

+

or

push-button to set the

start time (15 minute steps);

Press the OK push-button to switch to the
1st end time (E1) of the selected program;

6

12

18

24

0

P

1

P

1

E

1

E

1

09.00

Press the

+

or

push-button to set the

end time (15 minute steps);

Press the OK push-button to switch to
the 2nd start time (S2) of the selected
program;

Repeat steps as described, until all start
and end times have been allocated as

desired,

Press push-button M to terminate the
setting program and to return to the

timer program.

1.3.1 Timer program

With the built-in timer, each weekday is

allocated to a time program for automatic
changeover between comfort and off-peak
temperature. Three time programs are

available with a specified number of switching
operations during the day, the switching

times of which can be individually set:

Program 1 (P1):

2 switching operations

Program 2 (P2):

1 switching operation

Program 3 (P3):

3 switching operations

The following switching times are set at the

factory for each week (changing between
comfort and off-peak temperature):

6

3

9

15

21

Mo

P1

S1

E1

S2

E2

S1

E1

S2

E2

S1

E1

S2

E2

S1

E1

S2

E2

S1

E1

S2

E2

E1

E1

S1

S1

P2

We

Fr

1

3

5

Tu

Th

Sa

Su

2

4

6

7

12

18

24

time

Comfort temperature

da

y

o

f

the

w

eek

6

00

7

00

23

00

9

00

16

00

23

00

After selecting the timer program, the

thermostat automatically switches to the
program set on the current day of the week.

1

6

12

18

24

0

P

1

P

1

S

1

S

1

2.5

Party function
Short-term change to the setpoint tempera-

ture within the timer program up until the
next switching time.

1

6

12

18

24

0

P

1

P

1

1.8

Press

+

or

push-button to make a

short-term temperature change;

1

6

12

18

24

0

P

1

P

1

2.2

Press OK push-button to confirm. The timer
switching program now adopts the change

temperature until the next switching time.

1.3.2 Comfort temperature

Here, the preferred floor temperature during

the main period of use is set. In this
operating mode, the thermostat maintains
the set value by intermittent operation of the

floor temperature heating.

1

6

12

18

24

0

2.5

Press the

+

or

push-button to change

the setpoint value. Confirm by pressing the
OK push-button, otherwise the previously

set value will be restored after 20 seconds.

1.3.3 Off-peak temperature

Reduced value in comparison to the comfort
temperature, e. g. during the night-time hours.

1

6

12

18

24

0

1.8

Press the

+

or

push-button to change

the setpoint value. Confirm by pressing the

OK push-button, otherwise the previously
set value will be restored after 20 seconds.

1.3.4 Frost protection 7

Non-changeable setpoint value (dispaly 1.0),

which is activated at a floor temperature of
approx. 10 °C. All displays except the frost

protection symbol are extinguished after
approx. 20 seconds.