ons- in conformity with the information on
the unit rating plate - must be taken into
account.

The unit is to be fitted in such a way that
switching and control devices cannot be
touched by anyone in the bath or under
the shower.

If the sensor probe is damaged, short-
circuited or not connected, the heating
system will be switched off.

2.1 Installing the

temperature probe

Prior to fitting the top covering of the floor, the
temperature probe is to be let into an empty
tube flush with the surface in the foundation
flooring (for example the screed flooring);
see operating and installation instructions for
temperature controlled floor mat.

In the case of a fault live electricity
can be present in the controller or

sensor lead.

2.2 Installing the thermostat

The thermostat is to be inserted into a
standard commercial UP switch box for unit
diameters of 55 mm.
The thermostat is to be inserted as follows:
– Pull off the complete changeable frame (7,

8), to do this grasp the switch frame at the
top and bottom;

– Carry out the electrical connection in

accordance with the connection diagram
and as follows:
t The sensor probes are connected to

the 2 terminals marked „F“.

t The incoming mains electricity should

be connected as follows:

Live to „L“

Neutral to „N“

Earth to Earth terminal on backbox

t The heating mat/s connections should

be as follows:

Live to „L“

Neutral to „N“

Earth to Earth terminal on backbox

Length of temperature probe (DIN 44574)

4 m

Switching capacity

~ 16(2) A 230 V

Type

RTF-Z

Range of adjustment

ca. 10 ºC . . . 40 ºC

Protection class

ΙΙ

, acc. this manual

Switching difference

1 K

H x W x D

85 x 81,5 x 44,5 mm

Protection mode

IP 30 (after mounting)

Power reserve

4 days, after 1h of operation

Sensor characteristics value
Temperature R [kOhm] U [V]

20 °C

2,43

2,22

10 °C

3,66

2,49

40 °C

1,15

1,63

30 °C

1,65

1,92

50 °C

0,82

1,35

Approvals

see rating plate

4. Guarantee

3. Environment and

recycling

Recycling of obselete appliances

Appliances with this label must not
be disposed off with the general
waste. They must be collected

separately and disposed off according to local
regulations.

For guarantee please refer to the respective
terms and conditions of supply for your
country.

The installation, electrical connection
and first operation of this appliance

should be carried out by a qualified installer.

The company does not accept liability for
failure of any goods supplied which are not
installed in accordance with the
manufacturer's instructions.

– Insert the thermostat (9) into the switch

box and screw together;

– Replace the casing cover (7) and, if

appropriate, the switch frame (8) in addition.

The installation and operating
instructions for the floor heating unit,

to which the room thermostat should be
connected, has to be observed.

2.3 Hand-over

Explain the functions of the appliance to the
user. In particular, draw his or her attention
to the safety instructions. Hand over the
operating and installation instructions.

08709-000420