English – TIMBERK TAW H2 D User Manual

Page 5

Advertising
background image

5

ENGLISH

8. Cleaning and maintenance of the unit
Prior to cleaning make sure that the plug is disconnected from an outlet.
Otherwise it may result in an electric shock.
Before cleaning, wait until water in grooves is completely cooled down in
order not to burn hands.
8.1 To wipe the external surface of the unit use a damp and soft cloth.
To prevent an electric shock do not scratch and do not damage unit s
elements upon cleaning.
When cleaning the unit, do not use solvents, benzine, dimethylbenzene, hard
brush, talc powder and other substances other than water.
8.2 Remove the water tank, then take out the water tray and drain it, then
wipe remaining water inside the device under the tank with a damp and soft
cloth.
Add usual decalcifier to the tray, filled with water, allow it to hold for some
time; manually turn the disk pack several times. Then drain water and rinse
the tray and the disc pack.

To remove water remains on small parts you can use the brush, and then wipe
them again with a soft cloth. Clean the unit once or twice a wee

9. Troubleshooting
In case of emergencies resort to troubleshooting methods, given in tables.
If you are unable to solve issues by means of mentioned methods, contact
a service center.Life of the humidifier is 5 years.
Upon expiration of the humidifier it must be disposed in accordance with
regulations, rules and by means, currently in force at a disposal station.

7. Operation of the unit

To disconnect the unit again, press Power « ».

The choice of operating modes
To select one of four modes of operation, press the 6 button (selection
mode). Above the button will illuminate the appropriate indicator.

In eco-mode operation (indicator Econom) performance on humidifying
device will be 100 ml/h (fan speed 1100 RPM, power 32 W). In this mode,
the tank will be spent over 22 hours. The noise level will not exceed 30
dB (A).

In comfort mode (indicator Comfort) on the instrument performance
hydration of 180-220 ml/h (fan speed 1100 RPM, power consumption
200 watts). In this mode, the tank is used up in 12 hours. The noise level
will not exceed 30 dB (A). In this mode, for better performance on
humidifying device uses hot air.

In intensive mode (LED Turbo) performance on humidifying device is
280-300 ml/h (fan speed 1600 rpm, power 380 W). In this mode, the tank
will be spent over 8 hours. The noise level will not exceed 40 dB (A). In
this mode, for better performance on humidifying device uses hot air.
In automatic mode (the LED Auto) performance on humidifying device is
automatically adjusted.
If the humidity is 50-60% and above, includes economical mode
Econom.
If the humidity level of 40-50%, included a comfortable mode of
Comfort.
If the humidity is 40% or less, included intensive mode Turbo.

Indication of level of relative humidity
In the process of the device in the display area is displayed through the
plastic of the current level of relative humidity in the room (figure).
The optimum relative humidity for a man of 40-60%.

In addition, the device is equipped with a color indicator of moisture.
The vertical luminescent band in the center of the device changes color
depending on the level of relative humidity.
White LED indicates that the air is dry enough (40% and below).
Blue indicator light shows that air in the room good, moist (40-60%).
Green light indicates that the air is excessively humid (60% and above).

Blocking panel

To protect user-selected settings control panel can be locked. To do this
within 3 seconds to hold the lock button 8.

Timer to shut down

By clicking on the timer, you can choose the time after which the device
will automatically shut off:
" " - Shut off after 2 hours,
" " - Off after 4 hours
" " - Off in 6 hours
" " - Shut off after 8 hours.

www.timberk.com electric air washer (purifier)

Advertising