RS-232C Interface

Control of this unit via a computer is possible by connecting the computer to this unit with a RS-232C cross
cable (D-Sub 9 pin).

The command between this unit and the computer consists of “Header”, “Unit ID”, “Command”, “Data” and “End”.

z

Header (1 byte), Unit ID (2 bytes), Command (2 bytes), Data (n bytes), End (1 byte)

„

Header

This binary code indicates the start of communication.

„

Unit ID

This code specifies the unit. The binary code is fixed at “8901”.

RS-232C Specifications

Pin No.

Signal

Operation

Signal Direction

2

RxD

Receive data

This unit

 PC

3

TxD

Transmit data

This unit

 PC

5

GND

Signal ground

b

1, 4, 6 b 9

N/C

b

b

z

PC refers to the controller such as a personal computer.

Mode

Non-synchronous

Character Length

8 bit

Parity

None

Start Bit

1

Stop Bit

1

Data Rate

19200 bps

Data Format

Binary

Command Format

Binary code

Type

Description

21

Operating command

PC

 This unit

3F

Reference command

PC

 This unit

40

Response command

This unit

 PC

06

ACK

This unit

 PC

(When the command is accepted without error, it returns to PC)

1

6

5

9

This unit

D6 D7

D4 D5

D2 D3

D0 D1

Start Bit

Stop Bit

DLA-HD100U_EN.book Page 44 Monday, February 25, 2008 4:53 PM