Chapter 11, 3 remote control connection & operation – Acnodes RMQ 8170 User Manual

Page 38

Advertising
background image

P.34

Chapter 11

11.3 Remote Control Connection & Operation

}

}

}

}

2.3 The configuration of the status code for both normal and alarm operations:

There are total 2 bytes of the status codes. Byte one, the first 8 bits, shows the current status of the operation
modes that the unit is in. Byte two, the second 8 bits, shows the current status of the alarm operations of the
unit.

BYTE 1

BYTE 2



START

STOP

START

STOP




BYTE 1: Status code for normal operation modes

b7

b6

b5

b4

b3

b2

b1

b0

LOCK

VCR

SEQU

QUAD

CH4

CH3

CH2

CH1


Channel Select

1110 = CH1

1101 = CH2

1011 = CH3

0111 = CH4


Display Mode

0 = Quad screen display

1 = Full Screen display


Auto-sequencing mode

0 = Auto sequencing mode

1 = Quad or full screen mode

VCR mode

0 = VCR operation

1 = Live operation

Security Lock mode

0 = Security lock ON mode

1 = Security lock OFF mode

Menu Setup mode

00 = Menu setup mode

Advertising