ACR&Artex RCL-100D User Manual

Page 11

Advertising
background image

Y1-03-0138V

11

Master

Controller Wire

Searchlight

Cable Wire

Power Source

Lead

Function

Orange

+12 VDC or +24

VDC**

Power

Blue

Ground

Ground

Yellow

Yellow

Lamp Power

Green

Green

Lamp Ground

Red

Red

Up

White

White

Down

Black

Black

Right

Brown

Brown

Left

Table 1

WARNING: This wire MUST be fused with a 15 amp fuse in the

Master Controller's in-line fuse-holder.

Wiring to Searchlight
The RCL-100 Searchlight is supplied with a 15 foot integral wire
harness. This wire harness is cut to this length specifically to allow for
a voltage drop. Shortening the harness will decrease the life of the
bulbs. Any extra length of wire harness should be loosely coiled in a
convenient place. For best performance, the controller should be
attached to the end of the 15' Searchlight wire harness. If you must
lengthen the wire harness, use heavy duty wire to minimize the
voltage drop. This is especially important for the YELLOW lamp
power and GREEN lamp ground wires.

Following the wiring scheme shown in Table 1 use the supplied butt
connectors to connect the Master Controller to the Searchlight.

Wiring to Point Pad™
The RG-

59 Coax cable is supplied without the “F” connectors

attached for ease of routing. After the coax has been routed, strip the
insulation and crimp the “F” connectors in place. Screw the “F”
connectors to the Master Controller and the Point Pad™.

Wiring to Power Supply
The power source must be a fused 12 VDC, 10-amp supply or 24
VDC, 5-amp supply. Following the wiring scheme in Table 1, use the
supplied butt connectors to connect the Master Controller to the
Power Source. Refer to Table 2 for proper wire size for connection of
the input power lines.