background image

Y1-03-0138V

14

Master

RCL-100

Point Pad

Spotlight

Yellow

Lamp Power

Green

Lamp Ground

Red

Spot Up

White

Spot Down

Brown

Spot Left

Black

Spot Right

Other RCL-100 Point Pads

75 ohm TV Coaxial Cable

75 ohm TV Coaxial Cable

“T” Connector or Optional
75 Ohm Splitter for Multiple
RCL-100 Point Pads

Ground

Blue

Orange

Note: Wiring must be in accordance with this diagram. Improper wiring will damage components.

12 VDC or
24 VDC

Master Controller
in-line 15 amp fuse

Power Source Fuse

Figure 7 - URC-102 Master Controller Wiring Diagram