9.2.3.

POWER_OFF

This command powers off the card inserted in the card reader.

Command format

Header

Instruction

Data length

LEN

01 H

81 H

00 H

00 H

Response data format

Header

Status

Data length

LEN

01 H

9.2.4.

EXCHANGE_TPDU_T0

To exchange an APDU (Application Protocol Data Unit) command/response pair, between the MCU
card inserted in the AET65 and the host computer.

Command format

Header

Instruction

Data length LEN

Data

MSB

LSB

T0 TPDU

01 H A0 H

………

LEN

Length of APDU command data, N

Data

T0 TPDU to be sent to the card

Case 1: CLA INS P1 P2

Case 2: CLA INS P1 P2 Le

Case 3: CLA INS P1 P2 Lc Data

Case 4: Not supported. The driver/application should break case 4 command into
case 3 + case 2 commands.

Response data format

Header

Status

Data
length

BYTE
1

BYTE
N

SW1

SW2

LEN

01 H

BYTE x

Response data from card (if any).

SW1, SW2 Status code returned by the card.