5.0. PICC Commands for General Purposes

5.1. Get Data

The “Get Data command” will return the serial number or ATS of the “connected PICC”.

Command Class

INS

P1

P2

Le

Get Data

FF

CA

00
01

00

00

(Full Length)

Table 4: Get UID APDU Format (5 Bytes)

Response

Data Out

Result

UID

(LSB)

UID

(MSB)

SW1

SW2

Table 5: Get UID Response Format (UID + 2 Bytes) if P1 = 0x00

Response

Data Out

Result ATS

SW1

SW2

Table 6: Get ATS of a ISO 14443 A card (ATS + 2 Bytes) if P1 = 0x01

Results

SW1

SW2

Meaning

Success 90

00

The operation is completed successfully.

Error 63 00

The operation is failed.

Error 6A 81

Function not supported.

Table 7: Response Codes

Example:
1. To get the serial number of the “connected PICC”

UINT8 GET_UID[5]={0xFF, 0xCA, 0x00, 0x00, 0x04};

2. To get the ATS of the “connected ISO 14443 A PICC”

UINT8 GET_ATS[5]={0xFF, 0xCA, 0x01, 0x00, 0x04};