Set the picc operating parameter, Table 40, Response format (1 byte) – ACS AET62 NFC Reader with Fingerprint Sensor User Manual

Page 21: Table 41, Command format (5 bytes), Table 42, Table 43, Picc operating parameter. default value = ff

Advertising
background image

Response

Data Out

Result

PICC Operating Parameter

Table 40: Response Format (1 byte)

7.5. Set the PICC Operating Parameter

This is used to set the PICC Operating Parameter of the reader.

Command

Class

INS

P1

P2

Le

Get

Response

0xFF 0x00

0x51

New PICC

Operating
Parameter

0x00

Table 41: Command Format (5 Bytes)

Response

Data Out

Result

PICC Operating Parameter

Table 42: Response Format (1 byte)

Bit Parameter

Description

Option

7

Auto PICC Polling

To enable the PICC Polling

1 = Enable
0 = Disable

6

Auto ATS Generation

To issue ATS Request whenever an
ISO14443-4 Type A tag is activated

1 = Enable
0 = Disable

5 Polling

Interval

To set the time interval between
successive PICC Polling.

1 = 250 ms
0 = 500 ms

4 FeliCa

424K

1 = Detect
0 = Skip

3 FeliCa

212K

1 = Detect
0 = Skip

2 Topaz

1 = Detect
0 = Skip

1

ISO14443 Type B

1 = Detect
0 = Skip

0

ISO14443 Type A
#To detect the Mifare
Tags, the Auto ATS
Generation must be
disabled first.

The Tag Types to be detected
during PICC Polling.

1 = Detect
0 = Skip

Table 43: PICC Operating Parameter. Default Value = FF

Document Title Here

Document Title Here

Document Title Here

AET62 Reference Manual

Version 1.00

Page 21 of 35

[email protected]

www.acs.com.hk

Advertising