ACR30 Reference Manual
Version 3.3 January 2009

Page 30 of 44

ACR30

Command format

Instruction

Code

Data

length

80

H

00

H


Response data format

ATR

ATR

Four bytes Answer-To-Reset read from the card.

The ATR bytes are read from the card with LSB first, i.e., the first bit read from the card is
the LSB of the first ATR byte.

9.2.3.2.

POWER_OFF (*)

This command powers off the card inserted in the card reader.

Command format

Instruction Code

Data length

81

H

00

H

Response data format

No

response

data

9.2.3.3.

READ_DATA (*)

To read the specified number of bytes from the specified address of the card inserted.

Command format

Instruction

Code

Data

length

Data

ADDR

LEN

90

H

03

H

ADDR

Byte address of first byte to be read from the card. The high byte of the address is
specified as the first byte of ADDR.

LEN

Number N of data bytes to be read from the card (0 < N

≤ MAX_R)


Response data format

BYTE

1

BYTE

2

BYTE

3

...

BYTE

N

PROT

1

...

PROT

L

BYTE x

Data bytes read from the card memory

PROT y

Bytes containing the protection bits of the data bytes read

(0...4 bytes)

Advertising