Appendix b: response status codes, Acr30 – ACS ACK30 Smart Keyboard User Manual

Page 42

Advertising
background image

ACR30 Reference Manual
Version 3.3 January 2009

Page 42 of 44

ACR30

Appendix B: Response Status Codes

The following table summarizes the possible status code bytes SW1, SW2 returned by the ACR30:

SW1

SW2

Status

90

00

OK – command successfully executed

90

01

OK – using T=1 protocol (only in response to the RESET command)

90

10

OK – synchronous protocol is used (only in response to the RESET
command). The exact card type should be selected by using the
SELECT_CARD_TYPE command.

60

01

No card type selected

60

02

No card in reader

60

03

Wrong card type specified

60

04

Card not powered up;
This status code is also returned in a response if the card was
temporarily removed during a card access.

60

05

Invalid Instruction Code

60

20

Card failure

60

22

Short circuit at card connector

62

01

Secret code verify failed

67

01

Command incompatible with card type

67

02

Card address error

67

03

Data length error

67

04

Invalid length of response (with READ command)

67

05

Secret code locked

67

12

APDU command aborted (only MCU-based card using T=1 protocol);
the command abortion may be caused by a card internal failure.