These steps apply to all spar mounting conditions.

ACU-RITE bracket kit instructions supercede this section.

• Adjust drill depths and fastener lengths as required.
When instructed on page 12: Adjust the leveling set screws as

follows:

1. Insert, but do not tighten 8-32 (M4) reading head screws.
2. Place a .001”-.003” shim between the leveling set screws and

mounting surface.

3. Adjust each set screw until a slight drag is felt on the shim.
4. Evenly tighten the 8-32 (M4) reading head mounting

screws.

• Contact your Authorized ACU-RITE Distributor should you require

additional assistance.

• Move the axis to its center of travel.
• Mark the axis for quick return to center.
• Determine encoder cable exit direction and adjust (see page 3).

• Drill / tap the first end mounting hole / attach the spar.
• Align to within .010” TIR. to -A-, drill / tap second end hole.
• Attach the spar / align to within .010” TIR. to -A-.

• Locate the spar with the underside flush with the axis parting line.
• Mark one end mounting hole location.

11

ACU-RITE

®

ENC150

Spar Installation Procedure

Center mounting

axis

Mark center

of axis

C

L

Align to within .010” TIR of -A-

Align top of spar to within

.015” of -A-

-A- = Axis travel

Axis parting line

-A- = Axis travel

1/4-20 x 1/2” BHCS & Flat washer .017” thk.

End mounting hole (typical)