c) Reduces the motor speed until reaching minimum. If pressed for 2”, the motor is switched off.

If pressed for 2” when the Filter Alarm is active, the HOUR counter is reset.

d) Starts the motor and increases the speed until reaching maximum

e) Activates/deactivates the sensor (AUTOMATIC or MANUAL mode).

In automatic mode the sensor is active and the LED L2 is on. The LEDs L1 indicate the running speed.

L1) The 4 GREEN LEDs signal the running speed.

L2) When the LED is GREEN it indicates AUTOMATIC mode. When it is off, it indicates MANUAL mode. When the

LED is RED, it indicates the Filter Alarm.

fiLter aLarm: Displayed for 30” when the motor is off:

After 30h of operation, the LED L2 turns RED. It indicates that the grease filters need to be cleaned.

After 120h of operation, the LED L2 turns RED and flashes; It indicates that the grease filters need to be cleaned and

the charcoal filters replaced. After cleaning the grease filters (and/or replacing the charcoal filters), restart the hour

counter (RESET) by pressing the key

e during display of the filter alarm.

gas sensor sensitiVitY:

The sensitivity of the sensor can be modified to suit your requirements. To modify the sensitivity, the appliance must be

in manual mode (i.e. the LED L2 must be off); If not, press the key

e. Modify the sensitivity by simultaneously pressing

the keys D and E. The set sensitivity is indicated by the 4 green LEDs. By means of buttons

c(-) and d(+) the desired

sensitivity is set (Fig. 18/S). Store the “new” sensitivity by pressing the key

e.

attention: to preVent damaging tHe sensor, do not use siLicone products near tHe Hood!

Grease filter: pay special attention to the grease filter - it must be cleaned at regular intervals, when the grease

filter alarm is shown. Instructions about the Filter Alarm are included in the Conttrols paragraph. Disassembly of the

grease filter: push the handle outwards and pull the filter downwards (Fig. 3). Wash the filter with neutral detergent.

Charcoal filters: Using the appliance as a Filtering Version requires the replacement of the charcoal fat regular

intervals, when the charcoal filter alarm shows. Instructions about the Filter Alarm are included in the Controls paragraph.

Disassembly of the charcoal filter: remove the grease filter by pushing the handle outwards and pulling it down (Fig.3);

Then remove the carbon filter after removing the two filter stops (Fig. 17).

Lighting:

- Halogen lamps. To replace the halogen lamps, open the cover by prising in the slots (Fig. 22). Replace with lamps of

the same type.

warning: do not touch the new lamp with bare hands.

- Neon. Remove the neon lamp guard by opening it out on the 2 sides (Fig. 19B); turn the neon lamp 90° on its own

axis and remove it. Replace with a neon lamp of the same type.

FRANCAIS

description

cette hotte est équipée d’un système automatique (advanced sensor control) pour gérer toutes les

fonctions de la hotte. grace à l’advanced sensor control, l’air de la cuisine reste pure et sans odeur, et celui,

sans intervention de la part de l’utilisateur. L’asc detècte toutes les vapeurs, odeurs et fumes émanantes de

la cuisson. L’asc, peut aussi, capter une présence de gaZ anormale dans la pièce.

L’appareil peut être en version recyclage ou en version aspirante.

Dans la version

à recyclage l’air et les vapeurs convoyés par l’appareil sont épurés par les filtres à charbon et

remis en circulation. ATTENTION: Dans la version recyclage il faut utiliser un filtre à charbon et un déflecteur d’air

(Fig.1A) qui, placé sur la partie supérieure de la structure, permet le recyclage de l’air dans la pièce.

Dans la version

aspirante, les vapeurs et les odeurs de la cuisine sont convoyées directement à l’extérieur par

un tuyau d’évacuation à travers le plafond (Fig. 2).

instaLLation

ATTENTION: Il faut au moins 3 personnes pour monter cet appareil; il est conseillé de confier les opérations

d’installation à des spécialistes. en outre, nous vous conseillons de suivre scrupuleusement toutes les phases

de montage et de vous assurer, lorsque vous aurez terminé, que l’appareil est solidement fixé.

Avant d’effectuer les opérations de montage, pour une maniabilité plus aisée de l’appareil, il faut extraire le filtre à

graisse : pousser la poignée vers l’extérieur, puis tirer le filtre vers le bas (Fig. 3).

Démonter également le cadre métallique en déposant les 4 vis de fixation (Fig. 4), débrancher la connexion de la

commande (Fig.4C), des lampes halogènes (Fig.4D) et des néons (Fig.4E).

Séparer la partie supérieure de la structure télescopique de la partie inférieure, en déposant les 4 vis de fixation

et les 4 rondelles (Fig. 5).

Conditions essentielles requises pour le montage : – Prévoir l’alimentation électrique à l’intérieur du tuyau télesco-

pique – Si votre appareil doit être installé en version Aspirante, prévoir le trou d’évacuation de l’air.