3.17 SPECIAL CONTROL SETTINGS


Special Control Settings p.7.2
Main RS422 Second. RS422
PGM1: EVS Remote -- [F5]Sony BVW75 04
PGM2:[F2]EVS Remote –- [F6]Sony BVW75 05
PGM3:[F3]EVS Remote –- [F7]---------- --
PGM4:[F4]EVS Remote –- [F8]---------- --

[Menu]Quit [Clr+F_]Dft [F9]PgUp [F0]PgDn


This page is used to define which device/controller can control which PGM

channel. For each PGM channel, you must define the main controller, selecting

from the list defined on page 7.1.

In LSM mode, the main controller for PGM1 must always be an EVS Remote.

This cannot be changed by the operator.

If the main controller is an EVS Remote, the RS422 port will be automatically

assigned and is not specified by the operator.

If the main controller is an EVS remote, it is then possible to specify a

secondary controller for that channel, that can be a protocol defined on page

7.1. The EVS remote controlling that channel can then decide at any time to

pass the control to, or to retrieve the control from the secondary controller.

Like for page 7.1, all EVS remotes must be the first in the list of Main

controllers, without gap. It is not allowed to have a protocol preceding an EVS

remote in this list.

A protocol (other than EVS AVSP or EVS IPDP protocols) can only be assigned

to 1 channel at a time.

EVS AVSP and IPDP protocols can be assigned to several channels

simultaneously. If you need to assign some channels to an AirBox, you must

set the main controller for these channels to EVS AVSP. If you need to assign

some channels to an IP Director, you must set the main controller for these

channels to EVS IPDP.

3.17.1 M

AIN

C

ONTROLLER FOR

PGM1

Possible values: EVS Remote
When working in LSM base configuration, the PGM1 main controller must always

be an EVS Remote. No other possible selection

3.17.2 M

AIN

C

ONTROLLER FOR

PGM2/3/4

Possible values: EVS Remote (default) + list of protocols-RS422 ports defined on

page 7.1