Insert live or delay window – EVS IPDirector Version 6.2 - June 2013 PLAYLIST PANEL User Manual User Manual

Page 87

Advertising
background image

select the T/C OUT radio button and enter a timecode value

select the Duration radio button and enter a duration value

6. Click the OK button.

The element is inserted in the list before or after the selected element (depending on the
"Insert mode in playlist" parameter of the Tools > Settings > Playlist > Playlist /
General
category. See section "General Settings" on page 142.

5.3.8.

Insert LIVE or DELAY Window

While inserting a train via the Insert LIVE or DELAY option of the Playlist Element
contextual menu, the Insert LIVE or DELAY window will open. This window makes it
possible to define an IN point and an OUT point for the train which will be inserted into the
playlist.

The window contains the following zones:

Field

Description

From
Which
Feed?

The drop-down list displays all trains available on the XNet network. If the
corresponding recorder has a defined name, this name is displayed in the
list otherwise its EVS technical name is displayed (i.e.: 29_XT1_REC1).

IN Zone

In this zone, the IN point of the inserted train can be defined. It can either

be based on a calculation when a delay is specified

be a fixed T/C value

IN Zone -
Delay

This defines the delay which is applied to the selected element when the
element is on air within the playlist. If the delay value exceeds the train
remaining capacity, a warning message will be displayed. The value
entered by the operator is still accepted, as the capacity could be made
available before the element is on air, by removing some clips stored on
the selected server.

IN Zone
– T/C IN

This defines the timecode from which the train will be played on. If the T/C
value is greater than the on-air T/C of the element, a warning message will
be displayed.

OUT
Zone

In this zone, the OUT point of the inserted train can be defined. It can have
one of the following values:

unknown

a fixed T/C value

a value calculated based on a duration from the IN point

OUT
Zone –
Unknown

The OUT point of the element is not known, it is an open end element.  The
element will be played out with the defined delay until an OUT point is
entered.

OUT
Zone -
T/C OUT

This defines the timecode until which the train will be played on. If the T/C
value is greater than the on-air T/C of the element, a warning message will
be displayed.

OUT
Zone -
Duration

This defines the duration for the element to be inserted in the playlist.

IPDirector - Version 6.2 - User Manual - Playlist Panel

5. Playlist Editing

73

Advertising