M&C TechGroup DIL-1_(H) Data sheet User Manual

Gas-dilution unit dil-1/(h), Special features, Application

Advertising
background image

M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany

[email protected] • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111

5.4

Embracing Challenge

ƒ

ƒ

Proven M&C-dilution technique

ƒ

ƒ

Operation at ambient temperature

ƒ

ƒ

Optionally heated to 180 or 320 °C

ƒ

ƒ

Integrated dilution preheater

ƒ

ƒ

No dew point problems

ƒ

ƒ

Dilution factor from 10:1 to 500:1

ƒ

ƒ

With test gas connection

ƒ

ƒ

Independent of the ambient
temperature

ƒ

ƒ

Easy maintenance and operation

Special Features

Gas-Dilution Unit DIL-1/(H)

DIL-1/H

Application

The non-heated or electrically heated M&C

dilution unit DIL-1 /H is used in analysis

technique to dilute the sample gas or com-

ponents in the sample for example in case of

toxic gases, moisture measurement or emis-

sion measurement.
The M&C dilution unit is based on the func-

tional dilution technique which is proved

since years in the M&C gas sample probe

SP2000-H/DIL.

Description

The M&C dilution units DIL-... are mounted on

a plate for wall mounting. The version DIL-1 is

not heated and works at ambient tempera-

ture. The version DIL-1/H is electrically heated

up to 180 °C . It is additionally equipped

with a lagged cover (version for 320 °C on

request).
A capillary thermostat controlls the tem-

perature, adjustable from 0-180 °C.

A high temperature limiter and a low tem-

perature alarm is included.
The connection of the heated lines is

made without cold bridges in the heated

part. Before the dilution gas enters the

dilution unit, it is heated up to operat-

ing temperature via a gas pre-heater. In

order to protect the dilution part against

contaminations, internal protective fil-

ters are installed for the sample gas and

the dilution gas stream. Calibration gas can be

feeded via the integrated connection.
A precision pressure controller with pressure

gauge is used for adjustment of the necessary

admission pressure of the dilution gas. Via a

vacuum pressure gauge, the function of the

dilution injector is controlled.
Both, pressure controller and pressure gauges

have to be ordered separately. Two versions

are available: Set -A (-A1) is mounted directly

on the mounting plate and control panel type

-S (-S1) is suitable for external 19» rack mount-

ing. A shut off valve and a flowmeter for

adjustment of the calibration gas are included

in the version -S (-S1).

The dilution unit can realize dilution ratios

of 10:1 to 500:1. In case of high dilution

ratios, a respective small quantity of gas

is sampled from the process. Optionally

a bypass injector -B (Option I) is available

integrated right in front of the dilution unit

in order to shorten the response time in case

of operation with atmospheric pressure or

low pressure. In case of option I, an additional

pressure controller is included in both mount-

ing versions.
The construction of the dilution unit guaran-

tees easy maintenance and operation inde-

pendent from process temperatures.