Technical data – M&C TechGroup DIL-1_(H) Data sheet User Manual

Page 3

Advertising
background image

M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany

[email protected] • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111

5.4

Technical specifications and illustrations are without

obligation, subject to modifications. 08.99/06.06

M&C-Dilution unit DIL-1/ (H)

Dilution rates with the critical orifices ”a“ - ”g“

a = 500

b = 200

c = 100

d = 50

e = 30*

f = 20

g = 10

: 1

Sample flow rate depending on the critical orifices
”a“- ”g“

a = 1,4

b = 2,7

c = 5,5

d = 11

e = 19*

f = 28

g = 55

l/hr

1)

Possibility to adapt the dilution factor

with dilution gas pressure-adjustment -5% bis +30%

2)

Dilution gas flow rate with injector version I or II

I: 480 - 600 Nl/hr, optional II: 1800 – 3000 Nl/hr

Dilution gas pressure on inlet of pressure controller

min. 4,5 bar g, max. 16 bar g

Bypass injector / B sample gas flow rate
gas pressure / gas flow rate

approx. 2 bar
injector gas approx. 300 l/hr sample gas approx. 150 l/hr

Process pressure

0,9 to 2 bar abs.

Fault caused by process temperature variations

operation independent of process temperature

Fault caused by process low- or overpressure

no fault as long as the differential pressure ∆P at the dilution unit is > 0,5 bar g and test gas is given to
the probe under process conditions

Fault caused by atmospheric pressure variations

< 1% with a variation of 50 mbar

Materials in contact with the sample gas

stainless steel 316 / 316Ti, quartz glass, FPM, graphite

Power supply for DIL-1/H

230V 50Hz, 800W

Temperature controller for DIL-1/H

capillary thermostat adjustable 0-180 °C , with high temperature limiter
and low temperature alarm as changeover contact, voltage free
alarm point ∆T30 °C to TSet, contact rating max. 250V 3A~ 0,25A =

Weight

approx. 8 kg

Technical Data

Part-No.

Type

M&C-Dilution Unit DIL-1/ (H) with orifice ”e“ for dilution ratio 30 : 1 standard

20 S 4900

DIL-1

Dilution unit non heated

20 S 4905

DIL-1/H (a)

Dilution unit electrically heated to 180 °C , (a) to be added to the Part-No. for power 115V 60Hz

20 S 4925

Option I

Bypass injector - B

20 S 4930

Option II

Additional sample gas outlet undiluted

20 S 4205

DIL-1/-A

option: 1 pressure controller, 2 gauges, mounting set for dilution unit

20 S 4215

DIL-1/-A1

option: 2 pressure controllers, 3 gauges, mounting set incl. connector set for dilution unit with by-pass

20 S 4250

DIL-1/-S

option: mounting set with 1 pressure controller, 2 gauges, flowmeter, 2 ball valves

20 S 4260

DIL-1/-S1

option: mounting set with 2 pressure controllers, 3 gauges, flowmeter, 2 ball valve

Other executions on request.

* Standard, others to be indicated along with order, intermediate values possible.