INSTALLATION INSTRUCTIONS

3

M S D  

•   W W W . M S D P E R F O R M A N C E . C O M   •   ( 9 1 5 )   8 5 7 - 5 2 0 0   •   F A X   ( 9 1 5 )   8 5 7 - 3 3 4 4

Limit

Lt Green

Accessories

Dark Blue

This wire activates the Launch Rev Limit and is the main reset wire for several features of the

Ignition. When 12 volts are applied to this wire it will activate the Launch Rev Limit. It also resets

the shift light and gear indicator to first gear. It also will select the Launch Retard value and Gear

1 curve. When 12 volts is removed, the Launch Ramp begins as does the Gear 1 curve.

When12 volts are applied the Slew Rate Rev limit will be disabled as well as the Timed Rev Limit

curve. When 12 volts are removed the Launch History begins recording.

Light Blue

Burnout Rev Limit. When 12 volts are applied the Burnout Rev Limit is active. This disables the

Acquisition function and Slew Rate Rev Limits and overrides other rev limits. It also resets the

Acquisition Record function.

It is recommended to have this wire switched from an outside source, such as the crew chief before

the burnout and while staging the car.

Spool-Up

When the Dark Blue and Light Blue wires are applied to 12 volts at the same time, a fourth rev

limit is activated. This limit is to spool up a turbo during the burnout. When both the Dark Blue

and Light Blue RevLimit wires are at +12 volts then the Spool RevLimit is active.

Retard Stage Wires or Gear Select

These three wires can be used as Retard Stage Activation and/or as a gear select wire.

Pink

Step1 retard enabled with +12 volt input and above Step1 Rpm value and Gear 2 Select.

Violet

Step2 retard enabled with +12 volt input and above Step2 Rpm value and Gear 3 Select.

Tan

Step3 retard enabled with +12 volt input and above Step3 Rpm value and Gear 4 Select.

Note:

When activated at the same time, these retard stages are added together. They are also

added with any Gear Retard Curve or Boost Retard values as well. Maximum retard is 30°.

Yellow

Shift Light output wire. It can handle up to 3 amps continuous to ground when enabled.

Brown/White RPM/Time/Pressure switch output wire. It can switch up to 3 amps continuous to ground

when enabled.

Yellow/Yellow Output for data acquisition or fuel controls. Note, only two wires are used.

3-Pin Connector, MAP Sensor

Connector Connects to an external MAP or gauge pressure sensor.
Brown/Violet +5 volt supply
Brown/Yellow Ground

Dark Brown Map Signal

Cam Synchronization

Fiber Optic This input requires the PN 7555 Inductive Sync Pickup. When this input is used, the 2-pin con-

nector is not. Note: If this input is not used, the plug or a cover should be installed.

2-Pin Connector

Lt Blue/

This 2-pin plug connects to Cam Sync Sensor, PN 2346, to indicate when cylinder number

one is firing. Note: When used, the fiber optic connector is not used and must be covered.