Renata SA 3V Lithium Coin Cells - DESIGNER'S GUIDE User Manual

Page 7

Advertising
background image

1) Standard discharge

current: 100% of nominal
capacity is obtained by
discharging the cells at
this current rates.

2) The maximum current is

determined for a yield of
70% of the nominal
capacity with a cut-off
voltage of 2.0V, at 23°C.
For currents exceeding
those given above or
pulsed current, please
contact Renata.

3) In applications where the

battery is exposed to tem-
peratures above 70°C,
please contact Renata for
consultancy.

7

6

the

swiss

power source

Electrical characteristics

Model

Nominal

Standard

Max. continuous

Operating

capacity

discharge current

discharge current

Temperature

(mAh)

(mA)

1)

(mA)

2)

(C)

3)

CR1025

30

0.05

0.40

-40/+85°

CR1216 MFR

30

0.10

1.00

-30/+70°

CR1220 MFR

40

0.10

1.00

-30/+70°

CR1225

48

0.10

1.00

-40/+85°

CR1616

50

0.10

1.00

-40/+85°

CR1620

68

0.10

1.00

-40/+85°

CR1632

125

0.20

1.50

-40/+85°

CR2016 MFR

90

0.20

3.00

-30/+70°

CR2025 MFR

165

0.30

3.00

-30/+70°

CR2032 MFR

225

0.40

3.00

-30/+70°

CR2320

150

0.20

3.00

-40/+85°

CR2325

190

0.30

3.00

-40/+85°

CR2430 MFR

300

0.50

4.00

-30/+70°

CR2430

285

0.50

4.00

-40/+85°

CR2450N

540

0.80

3.00

-40/+85°

CR2477N

950

1.00

2.50

-40/+85°

Advertising