Operator Instructions

Tire Pressure Control System Programming

Spicer’s Tire Pressure Control System features on location programming
through the Operator Control Panel. Programmable settings include:

• Individual pressure settings for the steer, drive and trailer axles.

• Loaded and unloaded axle programming for highway, off highway

and emergency condi tions.

• Overspeed warning for highway, off highway or emergency

conditions.

Enter the Tire Pressure Control System programming sequence by
pressing the SELECT and L/U buttons at the same time. A flashing bar
or psi verifies that you are in the programming mode and also indicates
that the first selection, English or Metric values, is ready for programming.
Refer to figure 4 for sample procedure.

Press up/down arrows to select options or change settings (pressure or
speed) and press SELECT button to record a selection in memory and
move to the next step.

Press the SELECT button repeatedly to move through the program
steps, one step for each time the SELECT button is pressed. Refer to the
programming reference chart for specific Tire Pressure Control System
pres sure and speed programming steps.

To complete the programming sequence, or exit the programming mode,
continue to press SELECT button to step through to the end of the
procedure.

Note: If no buttons are pressed for more than one minute, the Operator
Control Panel will end the pro gramming sequence, saving any changes
made during programming.

Advertising