40

Service Codes

Group: 7P! (Codes 31, 32)

Low Air Supply (Codes 31, 32)

Is the governor

cutout pressure set

at 120-125 psig?

Reset governor cutout

pressure and retest system.

Refer to Service Manual

Is the pressure

switch plugged in?

Plug in pressure switch

and retest system.

Refer to Service Manual

Using the diagnostic tool, verify

pressure switch operation.

Does the

pressure switch

close above 110

psi?

Verify wiring:

Switch off ignition.
Disconnect ECU harness connector and
supply tank pressure switch connector.
Verify continuity between ECU harness
connector pin G3 and pressure switch
harness connector PRESS SW wire.
Verify other press switch wire is grounded.

Are

connections

OK?

Repair

harness and

retest.

Verify air system capacity by checking

supply tank pressure buildup time.

Does the

supply tank build

up pressure?

Service code is not active. Reverify

flowchart steps and wait for fault to reoccur.

Replace pressure switch

and retest system.

Refer to Service Manual

No

No

Yes

Yes

No

Yes

Yes

No

Use diagnostic tool to determine type of fault.

Pressure

switch failed. Open or

closed?

Is there a

short?

Repair harness

and retest.

Replace pressure
switch and retest.

Verify wiring:

Switch off ignition.
Disconnect ECU harness connector and
supply tank pressure switch connector.
Check for shorts between ECU harness
connector pins G3 and K2.

Repair vehicle air supply

system and retest.

Refer to Service Manual

No

Yes

Closed

No

Yes

Open