50

Service Codes

Configuration Error

Configuration Error

No

Use electrical schematic and truck build information

to determine appropriate harness configuration.

Disconnect ECU from harness.

Is Config 1

connected

properly?

Fault is not active. Reverify flowchart

steps and wait for fault to reoccur.

Repair harness and/or
config plug and retest.

If pressure targets, etc. were

previously changed, reprogram them.

Note: ECUs are not a typical cause of problems; however, if this fault reoccurs multiple times
and wiring harness has been confirmed to be good, ECU replacement may be necessary.

Yes

Yes

No

Is ECU

connector

round?

At round ECU harness connector,
check for proper connection of Config
1 (pin Z) to one of the following
(based on appropriate config plug):

Ground (pin F)
Power (pin H)
Float (no connection)

At rectangular ECU harness connector,
check for proper connection of Config 1
(pin G1) to one of the following (based
on appropriate config plug):

Ground (pin K2)
Power (pin K1)
Float (no connection)

Yes

No

Is ECU

connector

round?

At round ECU harness connector,
check for proper connection of Config
2 (pin M) to one of the following
(based on appropriate config plug):

Ground (pin F)
Power (pin H)
Float (no connection)

Yes

No

At rectangular ECU harness connector,
check for proper connection of Config 2
(pin G2) to one of the following (based
on appropriate config plug):

Ground (pin K2)
Power (pin K1)
Float (no connection)

Is Config 2

connected

properly?

Press HWY and RUN FLAT together.

Did display

return to normal?

No

Yes

Use truck build information to determine

appropriate OEM config file.

Download OEM config file to ECU

using PC diagnostics.

Retest.

Advertising