H8186-CB

INSTALLATIoN GUIDe

oPeration

H8186-CB energy meter communication board is an optional field-installable plug-
and-play accessory board for the H81xx energy meter that allows networking the
H81xx to an existing BACnet MS/TP control/data acquisition system. It features field
selectable baud rate (9600, 19200, 38400).

Product diagram

ON

1 2 3 4 5 6

ON

1 2 3 4 5 6

1

2

TX

RX

3

RX

4

TX

5

6

7

8

9

ALIVE

LITHIUM BATTERY

1.

RS-485 LED (TX):

Red LED; blinks to indicate that the H8186-CB is transmitting

data to the master.

2.

RS-485 LED (RX):

Red LED; blinks to indicate that the H8186-CB is receiving data

from the master.

3.

LED from Main Board (RX):

Green LED; blinks to indicate that the H8186-CB is

receiving data from the main board.

4.

LED from Main Board (TX):

Green LED; blinks to indicate that the H8186-CB is

transmitting data to the main board.

5.

“ALIVE” LED:

Green LED; should blink once per second to indicate normal

operation of the H8186-CB.

6.

Network Address DIP Switches:

Use these DIP switches to set the network

address for the H8186-CB.

7.

Connection to Energy Meter:

Install the H8186-CB in the energy meter by

inserting this connector into the connection slot at the top of the energy meter.

8.

Communication DIP Switches:

Use these DIP switches to set the H8186-CB

baud rate.

9.

RS-485 Communication Terminals:

Insert the RS-485 connector into these

terminals. See the Wiring Diagram section of this guide for instructions on wiring
the connector for 2-wire communications.

CAUTION! Danger of explosion if battery is incorrectly

replaced. Replace only with the same or equivalent type

recommended by the manufacturer. Dispose of used bat-

teries according to the manufacturer’s instructions.

data outPut sPecifications

kWh, Consumption
kW, Real power
kVAR, Reactive power
kVA, Apparent power
Power factor
Voltage, line to line
Voltage, line to neutral
Amps, Average current
kW, Real power ØA
kW, Real power ØB
kW, Real power ØC
Power factor ØA
Power factor ØB
Power factor ØC
Voltage, ØA to ØB
Voltage, ØB to ØC
Voltage, ØA to ØC
Voltage, ØA to Neutral
Voltage, ØB to Neutral
Voltage, ØC to Neutral
Amps, Current ØA
Amps, Current ØB
Amps, Current ШC