6 instrument modification, 1 interchanging adjustment modules – VEGA VEGABAR 25 User Manual

Page 23

Advertising
background image

VEGABAR 25

23

Instrument modification

6 Instrument modification

6.1 Interchanging adjustment

modules

The modular construction of VEGABAR allows
retrofitting, interchange or removal of adjust-
ment modules and the indicating module.
Retrofitting may be necessary e.g. when a
VEGABAR with factory settings should be
adapted to modified measurement condi-
tions. Data already saved (e.g. adjustment
values) are not saved in the adjustment mod-
ule but in an EEPROM of the oscillator and re-
adjustment is therefore not necessary.

The connection of the modules is made:
- on the adjustment module via a 4-pole plug

connection

- on the indicating module via screw termi-

nals.

Exchange of the adjustment module

Removal of the adjustment module
1

Separate VEGABAR from the power
supply

2

Loosen the screws on the cover of
VEGABAR or VEGADIS 10

3

Loosen connection cable from the termi-
nals

4

Loosen screws of the adjustment cover

5

Remove adjustment cover and plug con-
nection

Insertion of an adjustment module
6

Plug the connection of the new adjust-
ment cover to the plug-in socket of the
oscillator

7

Fasten new adjustment cover

8

Fasten connection cables to terminals

9

Close cover of VEGABAR or VEGADIS 10

10 Connect VEGABAR to power supply

Retrofitting of an indicating module

1

Separate VEGABAR from power supply

2

Loosen screws on cover of VEGABAR or
VEGADIS 10

3

Remove cover

4

Connect indicating module to the screw
terminals via the four lines (note “3.3
Connection plan“)

Note:
Step 4 is facilitated when the indicating mod-
ule is temporarily (carefully) mounted with two
screws.

5

Place indicating module in the correct
position on VEGABAR or VEGADIS 10

6

Tighten screws of the cover

7

Connect VEGABAR to power supply

Indication
with LC-
display

VEGABAR

Module
without
adjustment

Module for
menu-guided
adjustment

Module for
basic
functions

Advertising