VEGA VEGAVIB 31-53 User Manual

Page 10

Advertising
background image

10

VEGAVIB

Oscillators

C - Contactless (VIB E40 C, E50 C), VEGAVIB 41, 43, 51, 52, 53

Power supply

20 … 250 V AC, 50/60 Hz
20 … 250 V DC

Output

contactless electronic switch

Domestic current requirement

< 5 mA (via the load circuit)

Load current

min. 10 mA, max. 400 mA (max. 4 A up to 40 ms)

The max. permissible ambient temperature is 60°C with a load current exceeding 300 mA.

R - Relay output (VIB E30 R, E40 R, E50 R), VEGAVIB 31, 41, 43, 51, 52, 53

Power supply

20 … 250 V AC, 50/60 Hz; 20 … 72 V DC
(the max. permissible ambient temperature de-
creases linearly from 70°C to 50°C between
60 V DC and 72 V DC)

Power consumption

approx. 1 … 8 VA, max. 1.5 W

Output

relay output

Relay data:
- contact

floating spdt

- contact material

AgCdO and Au plated

- turn-on voltage

min. 10 mV
max. 250 V AC, 250 V DC

- switching current

min. 10 µA
max. 3 A AC, 1 A DC

- breaking capacitance

max. 500 VA, 54 W

T - Transistor output (VIB E40 T, E50 T), VEGAVIB 41, 43, 51, 52, 53

Power supply

10 … 55 V DC

Power consumption

max. 0.5 W

Output

floating transistor output
NPN/PNP wirable

Load current

max. 400 mA (output - overload resistant and
permanently short-circuit proof)

Voltage loss

max. 1 V

Turn-on voltage

max. 55 V DC

Blocking current

< 10 µA

Z - Two-wire output (VIB E50 Z, E50 Z Ex), VEGAVIB 51, 52, 53

Power supply

12 … 36 V DC
(power supply via VEGATOR signal conditioning
instrument)

Output

two-wire output

Current consumption
- vibrating rod free

8 mA

- vibrating rod immersed

16 mA

Suitable signal conditioning instruments

VEGALOG 571
VEGATOR 425 Ex F, 525 F, 534 Ex, 536 Ex,
537 Ex, 636 Ex, 825 Ex

Product description

Advertising