10 supplement, 1 technical data – VEGA VEGABAR 61 Foundation Fieldbus User Manual

Page 53

Advertising
background image

10 Supplement

10.1 Technical data

General data

Pressure type

Gauge pressure or gauge pressure

Measuring principle

Depending on the measuring range ceramic-
capacitive or strain gauge (DMS), each with
isolating system

Communication interface

I

²C bus

Materials and weights

Material 316L corresponds to 1.4404 or 1.4435

Materials, wetted parts

-

Process fitting

316L

-

Diaphragm

316L, Hastelloy C276, Hastelloy C2, Tantalum,
Titanium, PTFE on 316Ti, 316L with gold-coating,
Hastelloy C4

Materials, non-wetted parts

-

Electronics housing

Plastic PBT (polyester), Alu die-casting powder-
coated, 316L

-

External electronics housing

plastic PBT (Polyester)

-

Socket, wall mounting plate external
electronics housing

plastic PBT (Polyester)

-

Seal between housing socket and wall
mounting plate

TPE (fixed connected)

-

Seal ring, housing cover

NBR (stainless steel housing), silicone (Alu/plastic
housing)

-

Inspection window in housing cover for
indicating and adjustment module

Polycarbonate (UL-746-C listed)

-

Ground terminal

316Ti/316L

-

Connection between IP 68 transmitter
and external electronics housing

PUR, FEP, PE

-

Type plate support with IP 68 version on
cable

PE hard

Weight approx.

0.8 … 8 kg (1.764 … 17.64 lbs), depending on
process fitting

Output variable

Output

-

Signal

digital output signal, Foundation Fieldbus protocol

-

Physical layer

according to IEC 61158-2

VEGABAR

61 • Foundation Fieldbus

53

10 Supplement

28258

-

EN

-081209

Advertising