VEGA VEGABAR 61 Foundation Fieldbus User Manual

Page 55

Advertising
background image

Input variable

Adjustment

Adjustment range of the min./max. adjustment relating to the nominal measuring range:

-

percentage value

-10 … 110 %

-

pressure value

-20 … 120 %

Adjustment range of the zero/span adjustment relating to the nominal measuring range:

-

zero

-20 … +95 %

-

Span

-120 … +120 %

11)

-

Difference between zero and span

max. 120 % of the nominal range

Adjustment range with measuring ranges from 100 bar, relating to the nominal measuring range:

-

zero/Min.

-5 … +95 %

-

span/Max.

-5 … +105 %

Recommended max. turn down

10 : 1 (no limitation)

Nominal measuring ranges and overload resistance

Nominal range

Overload, max. pressure Overload, min. pressure

Gauge pressure

0 … 0.4 bar/0 … 40 kPa

30 bar/3000 kPa

-0.8 bar/-80 kPa

0 … 1 bar/0 … 100 kPa

35 bar/3500 kPa

-1 bar/-100 kPa

0 … 2.5 bar/0 … 250 kPa

50 bar/5000 kPa

-1 bar/-100 kPa

0 … 100 bar/0 … 10 MPa

200 bar/20000 kPa

-1 bar/-100 kPa

0 … 250 bar/0 … 25 MPa

500 bar/50 MPa

-1 bar/-100 kPa

0 … 400 bar/0 … 40 MPa

800 bar/80 MPa

-1 bar/-100 kPa

0 … 5 bar/0 … 500 kPa

65 bar/6500 kPa

-1 bar/-100 kPa

0 … 10 bar/0 … 1000 kPa

90 bar/9000 kPa

-1 bar/-100 kPa

0 … 25 bar/0 … 2500 kPa

130 bar/13000 kPa

-1 bar/-100 kPa

0 … 60 bar/0 … 6000 kPa

200 bar/20000 kPa

-1 bar/-100 kPa

-1 … 0 bar/-100 … 0 kPa

35 bar/3500 kPa

-1 bar/-100 kPa

-1 … 1.5 bar/-100 … 150 kPa

50 bar/5000 kPa

-1 bar/-100 kPa

-1 … 5 bar/-100 … 500 kPa

65 bar/6500 kPa

-1 bar/-100 kPa

-1 … 10 bar/-100 … 1000 kPa

90 bar/9000 kPa

-1 bar/-100 kPa

-1 … 25 bar/-100 … 2500 kPa

130 bar/13000 kPa

-1 bar/-100 kPa

-1 … 60 bar/-100 … 6000 kPa

200 bar/20000 kPa

-1 bar/-100 kPa

-0.2 … 0.2 bar/-20 … 20 kPa

30 bar/3000 kPa

-1 bar/-100 kPa

-0.5 … 0.5 bar/-50 … 50 kPa

35 bar/3500 kPa

-1 bar/-100 kPa

0 … 2.5 bar/0 … 250 kPa

50 bar/5000 kPa

-1 bar/-100 kPa

Absolute pressure

0 … 1 bar/0 … 100 kPa

35 bar/3500 kPa

0 bar abs.

11)

Values less than -1 bar cannot be set.

VEGABAR

61 • Foundation Fieldbus

55

10 Supplement

28258

-

EN

-081209

Advertising