VEGA 145 Safety barrier User Manual

Page 3

Advertising
background image

Technical Information

Type 145

3

Technical data

Input

Input voltage

from the signal conditioning instrument
22 … 24 V DC

Input current

4 … 20 mA

Output

Output voltage to the
transducer
(dependent on sensor current)

12 … 16 V

Output circuit
(intrinsically)

4 … 20 mA

Flame proofing intrinsic safety

EEx ia IIC

Max. values

U

max.

23,1 V

I

K

126 mA

P

max.

0,73 W

Max. permissible outer
inductance

0,5 mH

Max. permissible outer
capacitance

56 nF

Max. resistance per conductor
(to the sensor)

15 Ohm

General data

Isolation
Input / output circuit

galvanically

Testing voltage

4000 V eff.

Power consumption

300

µ

A;

±

60

µ

A

Terminals

max. 2 x 1,5 mm

2

Material

housing

ABS, grey

Protection

housing

IP 40

terminal

IP 20

Mounting

on carrier rail
TS 32 acc. to EN 50 035
TS 35 x 7,5 acc. to EN 50 022

Permissible ambient temperature

–20

°

C … +70

°

C / –4 … +158

°

F

Storage and transport temp.

–20

°

C … +90

°

C / –4 … +194

°

F

Error limits

Linearity error

< 0,2 %

Temperature influence

< 0,08 % / 10 K

Advertising