background image

VEGABAR 15

5

Product description

1)

Similar to DIN 16 086, reference conditions acc. to IEC 770: Temperature 15°C … 35°C; rel. moisture
45 % … 75 %; pressure 860 mbar … 1060 mbar/86 kPa … 106 kPa

2)

In compensated temperature range from 0°C … +80°C, reference temperature 20°C.

3)

Maintaining the housing protection requires the use of a seal that correctly fits the cable in the cable entry.
If the supplied seal does not fit, a suitable seal must be provided by the customer.

Protective measures

Protection

1)

IP 65

Protection class

III

Overvoltage category

III

Connection

Cable entry

Pg 9 (DIN 43 650)

Materials, wetted parts

Process connection

stainless steel 1.4404

Diaphragm
- internal sensor element

stainless steel 1.4404

- flush version

stainless steel 1.4401

Materials, non-wetted parts

Housing
- internal sensor element

stainless steel 1.4404

- flush version

stainless steel 1.4301

Connection plug

PA

Weight

VEGABAR 15

approx. 300 g

CE conformity

VEGABAR 15 process pressure transmitters meet the protective regulations of EMC
(89/336/EWG) and NSR (73/23/EWG). Conformity has been judged acc. to the following
standards:
EMC

Emission

EN 50 081 - 1: 1992

Susceptibility

EN 50 082 - 2: 1995

NSR

EN 61 010 - 1: 1993