3 technical data – VEGA BGT 596-596 Ex.M User Manual

Page 4

Advertising
background image

4

Carrier BGT 596, 596 Ex.M

Operating instruction

1.3 Technical data

BGT 596

Mechanical data

Dimensions

W x H x D = 482,6 (19“) x 132,5 x 254

Module positions

choice out of 84 positions

Connection of protector

tongue 2 x 6,3 x 0,8

Blind cover

4 TE (4 x 5,08 = 20,32 mm)

Protective measures

Wiring side

IP 00

Upper and lower side

IP 00

Front side (completely equipped)

IP 30

IP 40 (with series 500 new)

Module (consisting of)

Guide rails

2 pcs.

Instrument coded key

2 pcs.

Fixing screw

2 pcs. M2,5

Multipoint connector

1 pce.

- type

DIN 41 612, series F, 32-/33-pole, d, b, z

- connection

see following list

Wire-Wrap 1,0 x 1,0 mm

Article no. Module-

33 A

32 A

Plug 2,8 x 0,8 mm

33 B

32 B

Termi-Point 1,6 x 0,8 mm

33 C

32 C

Soldering connection

33 D

32 D

Screw connection

33 E

––

Connection for signal conditioning

VEGATOR

521

525 F

instruments

522

523
527

VEGAMET

513

507 Z

514, 514 V

514 D,
514 VD

515, 515 V

VEGASEL

543, 544

545, 546
547

VEGACOM

557

1)

VEGASTAB 593-60, 593 and 594 power supply
units are offered completely, i.e. inclusive

module as multipoint connector series H, 15-pole

with plug 6,3 mm

1)

(with earth terminal for screened cable)

Advertising